AUTOMATA 

AUTOMATA GmbH & Co. KG Gewerbering 5 D-86510 Ried
Phone: +49(0)8233 7916-0
Fax: +49(0)8233 7916-99 info.de@cannon-automata.com

AUTOMATA S.p.A.• Via G. Carducci, 705 • I-21042  Caronno Pertusella (VA)
Phone: +39 (02)9639970FAX: +39 (02)96399731info.it@cannon-automata.com

This site uses cookies to enable a better customer experience. By continuing to browse the site you are agreeing to our use of cookies.
Please find more information about cookies in our Data Privacy Statement.


Close
 

follow us 

facebook 

PSUBR

I/O MODULE Power supply  with access to F3 IO bus

61KZ010263 PSU BR

  • 5 V / 3 A main output
  • High conversion efficiency
  • Auxiliary 24 V/ 2 A electronic protected output
  •  Overcurrent and short circuit protection
  • Integrated bus termination resistor
  • status and diagnostic LEDs
  • RJ-45 connector

 

General Data
Housing dimensions  (Width x height x depth)22.5 mm x 99.0 mm x 114.5 mm
Weight95 g (without  connectors), 107 g (with connectors)
Permissible operating temperature+5° to +55°C
Permissible storage and transport temperature-25° to +85°C
Permissible humidity10% to 95%, not condensing
Permissible air pressure  (operation)80 to 106 kPa (up to  2000 m above sea level)
Permissible air pressure  (storage and transport)70 to 106 kPa (up to3000 m above sea level)
Degree of protectionIP20 according to IEC 60529
Connection method for connectorsSpring cage terminals
Conductor cross-section (power connector)0.2 to 2.5 mm2 (24 – 12 AWG)
Functional earth connectionTo the DIN rail with spring contact
Mode state visual indicatorsInput power (POWER), bus power 1 (BP1) and bus power 2 (BP2) LED lamps on front panel

 

Power supply
Main power supply VM24 V DC (-15% ÷ + 20% according to IEC 61131-2)
Maximum allowed ripple5% of supply voltage (according to IEC 61131-2)
Current consumption from main supply3 A max
Supply overvoltage protection on VMUnidirectional Zener clamp (Vz > 30 V)
Supply reverse polarity protectionInput shunt diode, reverse connected
Supply fuse5 A, not replaceable by the user
Input power visual indicatorsGreen LED lamp, lighted if supply is present (POWER)
Local bus power #15 V DC / 3 A, regulated
Local bus power #1 protectionsOvercurrent, catastrophic overvoltage
Local bus power #1 visual indicatorsGreen LED lamp, lighted if supply is present (5V)
Local bus power #224 V DC / 2 A, unregulated
Local bus power #2 capacitive load120 μF max
Local bus power #2 protectionsOvercurrent
Local bus power #2 visual indicatorsGreen LED lamp, lighted if supply is present (24V)

 

Bus termination
Bus termination resistor120Ω

 

Imprint|Data Privacy Polocy|Terms & Conditions